Residential NFPA 13D Fire Sprinkler Plan Revision and Hydraulic Calculations
Budget: $30 – $250 USD
Project Location: San Diego County, California
I am seeking an experienced residential fire sprinkler designer to revise an existing NFPA 13D fire sprinkler plan for a new single-family residence with a Junior Accessory Dwelling Unit, or JADU, in San Diego County, California.
The existing fire sprinkler drawings were designed using a 1¼-inch fire meter and underground water service. However, Valley Center Municipal Water District installed the following:
1-inch fire meter
1-inch service lateral from the water main
1-inch auxiliary double-check assembly
San Diego County Fire has directed me to submit revised fire sprinkler plans, hydraulic calculations, and product specification sheets directly to County Fire for review and approval.
Existing Documents
The current fire sprinkler package includes four sheets, F1 through F4.
A limited pressure calculation appears on Sheet F2, but a complete, separate, node-by-node hydraulic calculation report was not provided.
The selected designer must review the existing system layout and prepare a complete and defensible hydraulic calculation based on the actual installed 1-inch water service.
The following documents can be provided:
Existing F1 through F4 fire sprinkler drawings in PDF format
Full approved architectural plan set
Current architectural CAD files, if needed and available
Water district confirmation of the installed fire service components
Preliminary Project Information
NFPA 13D residential sprinkler system
New single-family residence with JADU
Approximately 75 feet from the fire service connection to the building
Approximately 14.5 feet of elevation rise from the service connection to the building
Preliminary available pressure assumption: 50 psi, subject to verification by the designer
Existing sprinkler head shown on plans: Senju RC-RES, K4.9
Actual installed fire meter, lateral, and auxiliary double-check assembly: 1 inch
The designer must determine whether the private underground fire line should remain 1¼ inches downstream of the 1-inch meter or be revised to 1 inch.
All final pipe sizes must be supported by the hydraulic calculations and acceptable to San Diego County Fire.
Scope of Work
The selected designer will be responsible for the following:
Review the existing F1 through F4 fire sprinkler drawings and the latest approved architectural plans.
Coordinate the sprinkler layout with the approved room dimensions, ceiling conditions, and building configuration.
Revise the water-supply information to accurately reflect:
1-inch fire meter
1-inch service lateral
1-inch auxiliary double-check assembly
Actual underground pipe length
Actual elevation rise
Prepare complete hydraulic calculations for the hydraulically most demanding sprinkler design area.
Include all applicable pressure losses, including:
Water meter loss
Double-check or backflow assembly loss
Underground fire-service piping
Elevation loss
Fittings and valves
Interior sprinkler piping
Sprinkler demand
Provide a clear node-by-node hydraulic calculation report.
Include an appropriate hydraulic safety margin above the minimum calculated system demand.
Identify and correct any conflicting, incomplete, or unsupported flow and pressure information in the existing plans.
Revise pipe sizes only where supported by the hydraulic calculations.
Update all affected plan information, including:
Riser diagram
Water-supply information
Pipe-size callouts
Sprinkler-head callouts
Notes
Legends
Material schedules
Hydraulic reference points
Design criteria
Assemble the applicable product specification sheets for:
Residential sprinkler heads
Underground and interior piping
Fire meter, if applicable
Auxiliary double-check or backflow assembly
Valves and other listed system components
Prepare a clean and coordinated package suitable for direct submission to San Diego County Fire.
Provide one reasonable correction cycle for County Fire comments related to this scope of work.
Required Deliverables
Corrected fire sprinkler plans in editable CAD format
Print-ready fire sprinkler plan set in PDF format
Complete hydraulic calculation report in PDF format
Hydraulic calculation file in editable or native software format
Applicable product specification sheets
Brief revision log summarizing all changes made
Response to one reasonable AHJ correction cycle related to the revised design
Required Qualifications
Please apply only if you have demonstrated experience with:
NFPA 13D residential fire sprinkler system design
Residential hydraulic calculations
AutoSPRINK, Hydratec, or equivalent hydraulic calculation software
California residential fire sprinkler requirements
Preparing fire sprinkler plans for fire department or AHJ review
Coordinating sprinkler drawings with architectural plans
Information to Include With Your Proposal
Please provide:
Examples of similar NFPA 13D residential fire sprinkler plans
Examples of complete hydraulic calculation reports
The hydraulic calculation software you use
Your experience with projects in California
Your experience with San Diego County Fire or nearby jurisdictions, if any
Your estimated cost and completion schedule
Confirmation that editable CAD and native hydraulic calculation files will be provided
Confirmation that one AHJ correction cycle is included
Confirmation whether you are licensed or otherwise qualified to sign or certify the plans if required by San Diego County Fire
The objective is to obtain a complete, accurate, and approvable NFPA 13D fire sprinkler package based on the actual installed 1-inch water service, and then provide the approved plans to a qualified contractor for installation. Here is the link to the full set of approved plan.
https://drive.google.com/file/d/1SAH61SCj_BCHzcM0rpsOHxalHqewbCmq/view?usp=sharing
I am seeking an experienced residential fire sprinkler designer to revise an existing NFPA 13D fire sprinkler plan for a new single-family residence with a Junior Accessory Dwelling Unit, or JADU, in San Diego County, California.
The existing fire sprinkler drawings were designed using a 1¼-inch fire meter and underground water service. However, Valley Center Municipal Water District installed the following:
1-inch fire meter
1-inch service lateral from the water main
1-inch auxiliary double-check assembly
San Diego County Fire has directed me to submit revised fire sprinkler plans, hydraulic calculations, and product specification sheets directly to County Fire for review and approval.
Existing Documents
The current fire sprinkler package includes four sheets, F1 through F4.
A limited pressure calculation appears on Sheet F2, but a complete, separate, node-by-node hydraulic calculation report was not provided.
The selected designer must review the existing system layout and prepare a complete and defensible hydraulic calculation based on the actual installed 1-inch water service.
The following documents can be provided:
Existing F1 through F4 fire sprinkler drawings in PDF format
Full approved architectural plan set
Current architectural CAD files, if needed and available
Water district confirmation of the installed fire service components
Preliminary Project Information
NFPA 13D residential sprinkler system
New single-family residence with JADU
Approximately 75 feet from the fire service connection to the building
Approximately 14.5 feet of elevation rise from the service connection to the building
Preliminary available pressure assumption: 50 psi, subject to verification by the designer
Existing sprinkler head shown on plans: Senju RC-RES, K4.9
Actual installed fire meter, lateral, and auxiliary double-check assembly: 1 inch
The designer must determine whether the private underground fire line should remain 1¼ inches downstream of the 1-inch meter or be revised to 1 inch.
All final pipe sizes must be supported by the hydraulic calculations and acceptable to San Diego County Fire.
Scope of Work
The selected designer will be responsible for the following:
Review the existing F1 through F4 fire sprinkler drawings and the latest approved architectural plans.
Coordinate the sprinkler layout with the approved room dimensions, ceiling conditions, and building configuration.
Revise the water-supply information to accurately reflect:
1-inch fire meter
1-inch service lateral
1-inch auxiliary double-check assembly
Actual underground pipe length
Actual elevation rise
Prepare complete hydraulic calculations for the hydraulically most demanding sprinkler design area.
Include all applicable pressure losses, including:
Water meter loss
Double-check or backflow assembly loss
Underground fire-service piping
Elevation loss
Fittings and valves
Interior sprinkler piping
Sprinkler demand
Provide a clear node-by-node hydraulic calculation report.
Include an appropriate hydraulic safety margin above the minimum calculated system demand.
Identify and correct any conflicting, incomplete, or unsupported flow and pressure information in the existing plans.
Revise pipe sizes only where supported by the hydraulic calculations.
Update all affected plan information, including:
Riser diagram
Water-supply information
Pipe-size callouts
Sprinkler-head callouts
Notes
Legends
Material schedules
Hydraulic reference points
Design criteria
Assemble the applicable product specification sheets for:
Residential sprinkler heads
Underground and interior piping
Fire meter, if applicable
Auxiliary double-check or backflow assembly
Valves and other listed system components
Prepare a clean and coordinated package suitable for direct submission to San Diego County Fire.
Provide one reasonable correction cycle for County Fire comments related to this scope of work.
Required Deliverables
Corrected fire sprinkler plans in editable CAD format
Print-ready fire sprinkler plan set in PDF format
Complete hydraulic calculation report in PDF format
Hydraulic calculation file in editable or native software format
Applicable product specification sheets
Brief revision log summarizing all changes made
Response to one reasonable AHJ correction cycle related to the revised design
Required Qualifications
Please apply only if you have demonstrated experience with:
NFPA 13D residential fire sprinkler system design
Residential hydraulic calculations
AutoSPRINK, Hydratec, or equivalent hydraulic calculation software
California residential fire sprinkler requirements
Preparing fire sprinkler plans for fire department or AHJ review
Coordinating sprinkler drawings with architectural plans
Information to Include With Your Proposal
Please provide:
Examples of similar NFPA 13D residential fire sprinkler plans
Examples of complete hydraulic calculation reports
The hydraulic calculation software you use
Your experience with projects in California
Your experience with San Diego County Fire or nearby jurisdictions, if any
Your estimated cost and completion schedule
Confirmation that editable CAD and native hydraulic calculation files will be provided
Confirmation that one AHJ correction cycle is included
Confirmation whether you are licensed or otherwise qualified to sign or certify the plans if required by San Diego County Fire
The objective is to obtain a complete, accurate, and approvable NFPA 13D fire sprinkler package based on the actual installed 1-inch water service, and then provide the approved plans to a qualified contractor for installation. Here is the link to the full set of approved plan.