-Pro-ject tittle: Distance Protection Relay performance analysis in microgrid
Deadline: 3/4 days,
progress: daily progress is required whatever you ll have done particular day
Basically we need to do simulation in matlab. This is draft methodology. You may refer the flowchart
From the flow chart I need to do the model IEEE 9bus consist of distance relay & machine learning.
OBJECTIVE & AIM
The main aim in this project is to investigate the distance protective relay performance in microgrids. To solve problem issue with overcurrent. An additional objective: -
i. To involve international standard power system with microgrid and conventional distance protective relay.
ii. To investigate the performance of the modelled distance relay in the presence of various multitude faults in grid-connected and islanded.
iii. To improve distance protection relay reliability with communication assisted or Machine Learning Classifier Algorithm.
PROBLEM STATE-MENT:
In both modes which is islanded and grid connected of Microgrids (MGs) have different short circuit levels. The fault level in islanded MGs is lower than grid connected MGs due to fault contribution of distributed generators is lesser than contribution of microgrids.
PV inverters as one of main part in PV system also has fault contribution and itβs limited by its control system in order to protect the internal power electronic devices. The other impact is the phase angle of fault current contribute in PVIs is very unpredictable due to its dependence on PVIs support grids. Therefore, PV-MGs setting and coordinate the overcurrent relay are almost unworkable. Hence, the conventional current-measurement based fault detection techniques, which is used for primary distribution system protection can be highly unreliable when it comes to MGs protection.
I was asked to use this iEEE 9bus. And just need to add on the distance protection relay & machine learning to classified the fault, Type ieee 9bus. This model was there in Simulink tools, From the model its from wind power farm.
* Develop model with implementation of distance protection relay & machine learning as per flowchart
* You will do the simulink model, but you need to brief about output. Make sure it's understandable that the project objective is achieved!
Note: I attach a file and two pictures
Deadline: 3/4 days,
progress: daily progress is required whatever you ll have done particular day
Basically we need to do simulation in matlab. This is draft methodology. You may refer the flowchart
From the flow chart I need to do the model IEEE 9bus consist of distance relay & machine learning.
OBJECTIVE & AIM
The main aim in this project is to investigate the distance protective relay performance in microgrids. To solve problem issue with overcurrent. An additional objective: -
i. To involve international standard power system with microgrid and conventional distance protective relay.
ii. To investigate the performance of the modelled distance relay in the presence of various multitude faults in grid-connected and islanded.
iii. To improve distance protection relay reliability with communication assisted or Machine Learning Classifier Algorithm.
PROBLEM STATE-MENT:
In both modes which is islanded and grid connected of Microgrids (MGs) have different short circuit levels. The fault level in islanded MGs is lower than grid connected MGs due to fault contribution of distributed generators is lesser than contribution of microgrids.
PV inverters as one of main part in PV system also has fault contribution and itβs limited by its control system in order to protect the internal power electronic devices. The other impact is the phase angle of fault current contribute in PVIs is very unpredictable due to its dependence on PVIs support grids. Therefore, PV-MGs setting and coordinate the overcurrent relay are almost unworkable. Hence, the conventional current-measurement based fault detection techniques, which is used for primary distribution system protection can be highly unreliable when it comes to MGs protection.
I was asked to use this iEEE 9bus. And just need to add on the distance protection relay & machine learning to classified the fault, Type ieee 9bus. This model was there in Simulink tools, From the model its from wind power farm.
* Develop model with implementation of distance protection relay & machine learning as per flowchart
* You will do the simulink model, but you need to brief about output. Make sure it's understandable that the project objective is achieved!
Note: I attach a file and two pictures