Single Line Diagram and Site Plan for Hybrid Photovoltaic Energy Storage System
Budget: $30 – $250 USD
I need an electrical single line diagram and site plan for electrical permitting done within 8 hours or less! Only paying agreed price we agree to upfront, I will not pay over after the fact of award. You have plenty of information below and I will gladly provide site photos, address, and spec sheets for materials.
SYSTEM DESCRIPTION
Proposed hybrid photovoltaic energy storage system consisting of thirty-two (32) Canadian Solar CS1U-400MS 400W photovoltaic modules (12.80kW DC) roof mounted on existing metal shop structure. PV system interconnected to one (1) Sol-Ark 15K-2P hybrid inverter with integrated rapid shutdown, battery management, generator integration, and utility-interactive functionality.
Battery storage consists of six (6) EG4-LL 48V 100Ah lithium iron phosphate batteries installed in an EG4 server rack cabinet providing approximately 30.72kWh of storage capacity.
Generator backup consists of one (1) Generac 28kW standby generator connected to the Sol-Ark generator input terminal for automatic backup charging and emergency operation.
System configured as a whole-home backup installation serving the existing 200A residential service section of the existing 400A utility service. Sol-Ark inverter installed between utility service and backed-up house panel. Existing utility service remains interconnected for normal grid operation and net metering.
32 CANADIAN SOLAR CS1U-400MS MODULES
12.80 kW DC TOTAL
Roof-Mounted PV Array on Existing Metal Shop Building
|
| (2) PV Strings / DC Conductors
|
INTEGRATED RAPID SHUTDOWN
(NEC 690.12 Compliant)
|
|
SOL-ARK 15K-2P HYBRID INVERTER
120/240V, 1Ø, 60Hz
15kW Continuous AC Output
19.5kW Maximum PV Input
200A Grid Pass-Through Rating
Integrated Transfer Switch
Integrated Generator Input
UL 1741SB Listed
|
|--------------------|
| |
| |
| |
BATTERY BANK GENERATOR INPUT
6 x EG4-LL Generac 28kW
51.2V 100Ah 120/240V, 1Ø
Server Rack Batteries Standby Generator
30.72 kWh Total Auto Generator Start
|
|
GRID INPUT
Existing Utility Service
400A Service Entrance
Existing Utility Meter
|
|
BACKED-UP LOAD OUTPUT
200A Residential Service Section
(Main House Panel)
|
|
WHOLE-HOME BACKUP LOADS
Existing Residential Dwelling
NOTE:
Existing utility service is 400A.
Existing residential dwelling is supplied through a dedicated 200A residential service section.
Sol-Ark 15K-2P inverter is installed utilizing the existing 200A residential service section as the backed-up load panel in accordance with Sol-Ark whole-home backup configuration.
Generator connected to GEN terminals.
Battery bank connected to battery terminals.
PV array connected to inverter MPPT inputs.
System capable of grid-interactive, battery backup, generator-assisted, and islanded operation.
SYSTEM DESCRIPTION
Proposed hybrid photovoltaic energy storage system consisting of thirty-two (32) Canadian Solar CS1U-400MS 400W photovoltaic modules (12.80kW DC) roof mounted on existing metal shop structure. PV system interconnected to one (1) Sol-Ark 15K-2P hybrid inverter with integrated rapid shutdown, battery management, generator integration, and utility-interactive functionality.
Battery storage consists of six (6) EG4-LL 48V 100Ah lithium iron phosphate batteries installed in an EG4 server rack cabinet providing approximately 30.72kWh of storage capacity.
Generator backup consists of one (1) Generac 28kW standby generator connected to the Sol-Ark generator input terminal for automatic backup charging and emergency operation.
System configured as a whole-home backup installation serving the existing 200A residential service section of the existing 400A utility service. Sol-Ark inverter installed between utility service and backed-up house panel. Existing utility service remains interconnected for normal grid operation and net metering.
32 CANADIAN SOLAR CS1U-400MS MODULES
12.80 kW DC TOTAL
Roof-Mounted PV Array on Existing Metal Shop Building
|
| (2) PV Strings / DC Conductors
|
INTEGRATED RAPID SHUTDOWN
(NEC 690.12 Compliant)
|
|
SOL-ARK 15K-2P HYBRID INVERTER
120/240V, 1Ø, 60Hz
15kW Continuous AC Output
19.5kW Maximum PV Input
200A Grid Pass-Through Rating
Integrated Transfer Switch
Integrated Generator Input
UL 1741SB Listed
|
|--------------------|
| |
| |
| |
BATTERY BANK GENERATOR INPUT
6 x EG4-LL Generac 28kW
51.2V 100Ah 120/240V, 1Ø
Server Rack Batteries Standby Generator
30.72 kWh Total Auto Generator Start
|
|
GRID INPUT
Existing Utility Service
400A Service Entrance
Existing Utility Meter
|
|
BACKED-UP LOAD OUTPUT
200A Residential Service Section
(Main House Panel)
|
|
WHOLE-HOME BACKUP LOADS
Existing Residential Dwelling
NOTE:
Existing utility service is 400A.
Existing residential dwelling is supplied through a dedicated 200A residential service section.
Sol-Ark 15K-2P inverter is installed utilizing the existing 200A residential service section as the backed-up load panel in accordance with Sol-Ark whole-home backup configuration.
Generator connected to GEN terminals.
Battery bank connected to battery terminals.
PV array connected to inverter MPPT inputs.
System capable of grid-interactive, battery backup, generator-assisted, and islanded operation.