WOOD FRAMING STRUCTURAL CALCULATION REPORT
Budget: $30 – $250 USD
I am looking for someone to develop a WOOD FRAMING STRUCTURAL CALCULATION REPORT for a residential building in accordance with local building codes. This report will not need to be certified.
The successful candidate will be able to provide technical competence in conventional wood framing and structural calculations using appropriate terminology, code requirements, and best practices. The candidate should have a knowledge of load paths, lumber spans, and the ability to determine appropriate fastener types and sizes.
The report should meet all applicable local building codes and include detailed calculations, drawings, and sketches. The completed report should provide a clear and concise explanation of the structural decisions, system capacity, and design criteria. Finally, the report should include verification of the design for all superimposed loads, snow, wind, and seismic conditions.
This project requires an experienced professional who can perform accurate, reliable, and timely calculations. If you think you have the qualifications and experience to create a top-quality WOOD FRAMING STRUCTURAL CALCULATION REPORT, I look forward to hearing from you!
Description:
I need the report of the wooden structures of a house, first level, attic mezzanine, ceiling structure and foundations ( concrete), from already elaborated plans, only the calculation report is needed , with the following data:
Plane of structure of the ceiling
-Mezzanine 20 psf live load, 10 psf dead load
attic structure (20 live psf, 10 dead psf)
first floor structure (40 live psf, 12 dead psf)
Calculations with corresponding items labeled with #calc
Deflection criteria - L/480 live load, L/360 total load deflection
It is necessary that the report be prepared in English and in the English system ( inches and feet), and that it agrees with the data of the plans, which have been made on the basis of other houses , with a calculate of structures, but for this it is not available, so it is what is requested.
Please read what is required, so that the quotation includes everything and the values of the offer are not changed when making queries. Enclose in offer examples of reports of similar structures of houses, but , will not take into account the offer.
Photos of the drawings are attached
The successful candidate will be able to provide technical competence in conventional wood framing and structural calculations using appropriate terminology, code requirements, and best practices. The candidate should have a knowledge of load paths, lumber spans, and the ability to determine appropriate fastener types and sizes.
The report should meet all applicable local building codes and include detailed calculations, drawings, and sketches. The completed report should provide a clear and concise explanation of the structural decisions, system capacity, and design criteria. Finally, the report should include verification of the design for all superimposed loads, snow, wind, and seismic conditions.
This project requires an experienced professional who can perform accurate, reliable, and timely calculations. If you think you have the qualifications and experience to create a top-quality WOOD FRAMING STRUCTURAL CALCULATION REPORT, I look forward to hearing from you!
Description:
I need the report of the wooden structures of a house, first level, attic mezzanine, ceiling structure and foundations ( concrete), from already elaborated plans, only the calculation report is needed , with the following data:
Plane of structure of the ceiling
-Mezzanine 20 psf live load, 10 psf dead load
attic structure (20 live psf, 10 dead psf)
first floor structure (40 live psf, 12 dead psf)
Calculations with corresponding items labeled with #calc
Deflection criteria - L/480 live load, L/360 total load deflection
It is necessary that the report be prepared in English and in the English system ( inches and feet), and that it agrees with the data of the plans, which have been made on the basis of other houses , with a calculate of structures, but for this it is not available, so it is what is requested.
Please read what is required, so that the quotation includes everything and the values of the offer are not changed when making queries. Enclose in offer examples of reports of similar structures of houses, but , will not take into account the offer.
Photos of the drawings are attached