Civil engineer or structural engineer for house design stamp.
Budget: $250 – $750 USD
We are designing a house and we need a civil engineer or structural engineer to do the structural design of the house and stamp it. We want someone who is license in the state of Nevada.
Guidelines below:
STRUCTURAL PLANS and CALCULATIONS: (2 sets), if applicable, must be prepared by a Nevada registered professional civil or structural engineer. All plans and calculations must bear the engineer’s original stamp and signature.
STRUCTURAL FOUNDATION PLANS/DETAILS: (3 sets), must include the following:
Indicate concrete compressive strength and dimensional size and depth for all continuous and isolated spread footings and stem walls for the entire structure, including basement and window wells, if applicable
Show minimum size, grade and number of reinforcing steel bars required for all continuous and isolated spread footings and stem walls for entire structure, including basement, if applicable
Show all concrete embed anchors; bolts, hold downs, post base anchors, etc. and spacing, with adequate detailing
Show thickness, reinforcing and vapor barrier requirements for all concrete slabs on grade
Show material, strength, thickness and reinforcing for all masonry or concrete basement walls, if applicable
STRUCTURAL FLOOR FRAMING PLANS/DETAILS: (3 sets), must include the following:
Size, grade and spacing of posts, columns, beams, girders, ledgers and all connection details
Size, grade, spacing of floor joists, or two (2) sets of engineered floor truss package, per our Engineered Wood Truss Guide
Indicate material, grade, span index and anchorage of structural floor sheathing
Provide floor opening details for stairs, shafts, etc.
Exterior & interior stud wall framing members, grade, height and spacing
Window and door header sizes
Specify all metal framing hangers and anchors used
Provide current ICC ES Evaluation Report numbers for all prefabricated framing components
STRUCTURAL ROOF FRAMING PLANS/DETAILS: Three (3 sets), must include the following:
Size, grade and spacing of posts, columns, beams, girders, ledgers and all connection details
Size, grade, spacing of roof and ceiling joists or two (2) sets of engineered roof truss package, per our Engineered Wood Truss Guide
Exterior & interior stud wall framing members, grade, height and spacing
Attic access openings, including walkways to attic furnaces and air handlers
Indicate material, grade, span index and anchorage of structural roof sheathing
Window and door header sizes
Specify all metal framing hangers and anchors used
BPG-182 5 2/17/2017
Provide current ICC ES Evaluation Report numbers for all prefabricated framing components
Guidelines below:
STRUCTURAL PLANS and CALCULATIONS: (2 sets), if applicable, must be prepared by a Nevada registered professional civil or structural engineer. All plans and calculations must bear the engineer’s original stamp and signature.
STRUCTURAL FOUNDATION PLANS/DETAILS: (3 sets), must include the following:
Indicate concrete compressive strength and dimensional size and depth for all continuous and isolated spread footings and stem walls for the entire structure, including basement and window wells, if applicable
Show minimum size, grade and number of reinforcing steel bars required for all continuous and isolated spread footings and stem walls for entire structure, including basement, if applicable
Show all concrete embed anchors; bolts, hold downs, post base anchors, etc. and spacing, with adequate detailing
Show thickness, reinforcing and vapor barrier requirements for all concrete slabs on grade
Show material, strength, thickness and reinforcing for all masonry or concrete basement walls, if applicable
STRUCTURAL FLOOR FRAMING PLANS/DETAILS: (3 sets), must include the following:
Size, grade and spacing of posts, columns, beams, girders, ledgers and all connection details
Size, grade, spacing of floor joists, or two (2) sets of engineered floor truss package, per our Engineered Wood Truss Guide
Indicate material, grade, span index and anchorage of structural floor sheathing
Provide floor opening details for stairs, shafts, etc.
Exterior & interior stud wall framing members, grade, height and spacing
Window and door header sizes
Specify all metal framing hangers and anchors used
Provide current ICC ES Evaluation Report numbers for all prefabricated framing components
STRUCTURAL ROOF FRAMING PLANS/DETAILS: Three (3 sets), must include the following:
Size, grade and spacing of posts, columns, beams, girders, ledgers and all connection details
Size, grade, spacing of roof and ceiling joists or two (2) sets of engineered roof truss package, per our Engineered Wood Truss Guide
Exterior & interior stud wall framing members, grade, height and spacing
Attic access openings, including walkways to attic furnaces and air handlers
Indicate material, grade, span index and anchorage of structural roof sheathing
Window and door header sizes
Specify all metal framing hangers and anchors used
BPG-182 5 2/17/2017
Provide current ICC ES Evaluation Report numbers for all prefabricated framing components