AutoCAD Mechanical Engineer Needed for Booster Pump Station Layout (DWG) – 3 Hours Delivery
Budget: $10 – $30 USD
Hi,
I need an urgent AutoCAD mechanical modification and I need someone who can start immediately.
I have:
* Existing Booster Station DWG.
* Pump manufacturer DWG (Front / Side / Top views).
Your task is:
* Keep the existing civil and architectural layout unchanged.
* Insert 6 identical pumps using the supplied DWG blocks at original scale (1:1).
* Arrange all six pumps in one row while maintaining proper maintenance clearances.
* Connect each pump to the existing DN1000 suction header and DN800 discharge header according to standard pump station design practice.
* Include check valves, isolation valves, dismantling joints, reducers, and fittings where required.
* Ensure there are no clashes with walls, columns, foundations, or existing structures.
* Deliver:
1. Updated DWG.
2. High-quality PDF.
3. Brief notes if any clashes or modifications are required.
Design Data:
* Suction Header: DN1000 PN16
* Discharge Header: DN800 PN16
* Design Head: 120 mWC
* Keep all building dimensions unchanged.
Can you start right now?
Please reply with:
1. Your delivery time.
2. Your fixed price.
3. Confirmation that you can complete it within the next 2–3 hours.
I need an urgent AutoCAD mechanical modification and I need someone who can start immediately.
I have:
* Existing Booster Station DWG.
* Pump manufacturer DWG (Front / Side / Top views).
Your task is:
* Keep the existing civil and architectural layout unchanged.
* Insert 6 identical pumps using the supplied DWG blocks at original scale (1:1).
* Arrange all six pumps in one row while maintaining proper maintenance clearances.
* Connect each pump to the existing DN1000 suction header and DN800 discharge header according to standard pump station design practice.
* Include check valves, isolation valves, dismantling joints, reducers, and fittings where required.
* Ensure there are no clashes with walls, columns, foundations, or existing structures.
* Deliver:
1. Updated DWG.
2. High-quality PDF.
3. Brief notes if any clashes or modifications are required.
Design Data:
* Suction Header: DN1000 PN16
* Discharge Header: DN800 PN16
* Design Head: 120 mWC
* Keep all building dimensions unchanged.
Can you start right now?
Please reply with:
1. Your delivery time.
2. Your fixed price.
3. Confirmation that you can complete it within the next 2–3 hours.
Related categories:
CAD/CAM
Solidworks
Mechanical Engineering
AutoCAD
Engineering Drawing
Drafting
Water Treatment
3D CAD
CAD / SolidWorks