Unique Electrical Installation Project Design for a 6-Apartment Building
Budget: $10 – $30 USD
Unique Electrical Installation Project Design for a 6-Apartment Building
Within the scope of a ready-made building project, the lighting and electrical installation design of a 6-apartment building, where each apartment is at least 100 m², will be carried out. The project plan may be pre-prepared; however, the electrical installation must be uniquely designed. The project is expected to be prepared using AutoCAD or similar software and delivered in DWG format. Details are as follows:
**Floor Plans and Section Drawings**
+Detailed plan drawings must be prepared for each floor, showing the electrical installation and lighting elements.
+Cable paths and lighting equipment must be clearly included in the section drawings.
+Cables must not pass through columns.
**Lighting Element Placement**
+The positions, types, and technical specifications of lighting fixtures must be indicated in the drawings.
+The placements must comply with national and international lighting standards.
**Installation Details**
+A maximum of 7 outlets can be connected to one socket line in each apartment.
+A maximum of 9 lighting points can be connected to one lighting line in each apartment.
+Each apartment must have at least 5 lines, including:
+++3 special lines (washing machine, dishwasher, oven),
+++At least 1 socket line, and
+++At least 1 lighting line.
**Technical Drawing Standards**
+All drawings must comply with technical drawing rules; scales and symbols must be complete and used correctly.
**CAD Requirements**
+All drawings must be prepared using AutoCAD or similar software and delivered in DWG format.
**Project Notes and Explanations**
+Numbered explanation notes must be added to the drawings.
+An explanatory list must be prepared for all symbols used.
Applicants are expected to have the technical expertise and AutoCAD experience necessary to design a unique electrical installation that meets the specified requirements. An example project will be provided for review if needed.
Within the scope of a ready-made building project, the lighting and electrical installation design of a 6-apartment building, where each apartment is at least 100 m², will be carried out. The project plan may be pre-prepared; however, the electrical installation must be uniquely designed. The project is expected to be prepared using AutoCAD or similar software and delivered in DWG format. Details are as follows:
**Floor Plans and Section Drawings**
+Detailed plan drawings must be prepared for each floor, showing the electrical installation and lighting elements.
+Cable paths and lighting equipment must be clearly included in the section drawings.
+Cables must not pass through columns.
**Lighting Element Placement**
+The positions, types, and technical specifications of lighting fixtures must be indicated in the drawings.
+The placements must comply with national and international lighting standards.
**Installation Details**
+A maximum of 7 outlets can be connected to one socket line in each apartment.
+A maximum of 9 lighting points can be connected to one lighting line in each apartment.
+Each apartment must have at least 5 lines, including:
+++3 special lines (washing machine, dishwasher, oven),
+++At least 1 socket line, and
+++At least 1 lighting line.
**Technical Drawing Standards**
+All drawings must comply with technical drawing rules; scales and symbols must be complete and used correctly.
**CAD Requirements**
+All drawings must be prepared using AutoCAD or similar software and delivered in DWG format.
**Project Notes and Explanations**
+Numbered explanation notes must be added to the drawings.
+An explanatory list must be prepared for all symbols used.
Applicants are expected to have the technical expertise and AutoCAD experience necessary to design a unique electrical installation that meets the specified requirements. An example project will be provided for review if needed.