TACAN Antenna

Job ID: 34482570

Budget: $30 – $250 USD

A. Sectional Tower Steel Structure: shall include the layout, design, fabricate, supply and installation of 3.0M x 3.0M area and 6.0M height of Tower with mechanical lifting systems of capacity 2000 Kgs for TACAN Antenna System and at least 150 Kgs for Component Parts which shall have complete safety features. Perimeter walkway on the top of the tower around the TACAN Antenna shall contain steel grid flooring finished with tubular steel guard railings. Walkable Stairways shall be made and attached to the sectional tower steel structure.

B. Structural Parameter The following design criteria shall be followed in the design and detailing of the structure. Live Load on Tower Top Platform 2.0 KN/m2 Live Load on Frame 0.5 KN/m2 Wind Load 1.00 KN/m2
C. Bearing Capacity Consider 1 Kg/Cm2