Licensed Texas MEP Engineer - Mixed Use Renovation
Budget: $25 – $50 USD
Need MEP Engineer for an 8,000 sf mixed use remodel design. This is a small town and they don’t require an MEP stamp on this plan set, but I prefer a licensed MEP, and have other projects coming up. This project encompasses four apartments on the second floor, and an open “white box” commercial/retail space on the first floor.
Using the provided autocad drawings you will deliver 2D CAD drawings (and PDF’s), generate a scope of work, and design intention.
Mechanical:
Size equipment and duct design
1- Manual J Calculations
2- Overall ducted HVAC design for entire house
3- Ducting plans (to accommodate provided structural plans)
4- Size, spec, model, location and detail for HVAC Rooftop Units
Electrical:
1 – Review/revise our current electrical drawings (calculate a load schedule, single line diagram, lightings -normal and emergency)
Plumbing:
1 – Gas line calculation schedule.
My draftsman has worked up an MEP set that needs to be revised, but there is a starting place to work from.
Please review current design attached and be in touch. We can start immediately.
CAD files:
https://drive.google.com/drive/folders/1KHuLyXy9ddMTz9dPLD0iwvGh6Q5Ly5mG?usp=sharing
PDF Combined set:
https://www.dropbox.com/sh/ssgzajbu70fsq1c/AABXcLTWyD-VyhKXLPZW8U2wa?dl=0
If you meet these qualifications and have the necessary skills and experience, please reply with samples of your work.
Using the provided autocad drawings you will deliver 2D CAD drawings (and PDF’s), generate a scope of work, and design intention.
Mechanical:
Size equipment and duct design
1- Manual J Calculations
2- Overall ducted HVAC design for entire house
3- Ducting plans (to accommodate provided structural plans)
4- Size, spec, model, location and detail for HVAC Rooftop Units
Electrical:
1 – Review/revise our current electrical drawings (calculate a load schedule, single line diagram, lightings -normal and emergency)
Plumbing:
1 – Gas line calculation schedule.
My draftsman has worked up an MEP set that needs to be revised, but there is a starting place to work from.
Please review current design attached and be in touch. We can start immediately.
CAD files:
https://drive.google.com/drive/folders/1KHuLyXy9ddMTz9dPLD0iwvGh6Q5Ly5mG?usp=sharing
PDF Combined set:
https://www.dropbox.com/sh/ssgzajbu70fsq1c/AABXcLTWyD-VyhKXLPZW8U2wa?dl=0
If you meet these qualifications and have the necessary skills and experience, please reply with samples of your work.
Related categories:
Building Architecture
Mechanical Engineering
Electrical Engineering
AutoCAD
Plumbing