Dialux Design for Sports Hall Lighting URGENTLY!!!!
Budget: £10 – £20 GBP
URGENTLY!!!!
I need a simple Dialux report for project for a sports hall measuring 37x22 meters ( measurements attached bellow) . The project involves calculating LUX with two different types of LED lights.
Ceiling height is 8.1m.
NEED to reach above 1000LUX
temperature 4000K
1 light specification.
POWER : 3 option 100W, 150W, 200W (use best to reach required LUX)
LUMEN : 160lm/w
CCT K : 4000K
CRI >80
Beam angle 30*90°
SIZE:
100W : 630*105*79,
150W : 918*105*59,
200W : 1207*105*59
Power factor >0.95
2 light specification
POWER 2 option : 120W, 200W
Lumen : 160lm/w
CCT : 4000K
CRI >80
Beam angle 110°
UGR - UGR21
SIZE:
120W : L415*W310*H120mm
200W : L487*W367*H120mm
Light 1 -
100W
η 95.99%
ΦLamp - 15366
ΦLuminaire - 15300
150W
η 95.99%
ΦLamp - 23050
ΦLuminaire -22126
200W
η 99.94%
ΦLamp - 30733
ΦLuminaire -30690
Light 2 -
200W
η 99.94%
ΦLamp -31100lm
ΦLuminaire -31082lm
120W
η 97.81%
ΦLamp - 19500
ΦLuminaire -19074
I need a simple Dialux report for project for a sports hall measuring 37x22 meters ( measurements attached bellow) . The project involves calculating LUX with two different types of LED lights.
Ceiling height is 8.1m.
NEED to reach above 1000LUX
temperature 4000K
1 light specification.
POWER : 3 option 100W, 150W, 200W (use best to reach required LUX)
LUMEN : 160lm/w
CCT K : 4000K
CRI >80
Beam angle 30*90°
SIZE:
100W : 630*105*79,
150W : 918*105*59,
200W : 1207*105*59
Power factor >0.95
2 light specification
POWER 2 option : 120W, 200W
Lumen : 160lm/w
CCT : 4000K
CRI >80
Beam angle 110°
UGR - UGR21
SIZE:
120W : L415*W310*H120mm
200W : L487*W367*H120mm
Light 1 -
100W
η 95.99%
ΦLamp - 15366
ΦLuminaire - 15300
150W
η 95.99%
ΦLamp - 23050
ΦLuminaire -22126
200W
η 99.94%
ΦLamp - 30733
ΦLuminaire -30690
Light 2 -
200W
η 99.94%
ΦLamp -31100lm
ΦLuminaire -31082lm
120W
η 97.81%
ΦLamp - 19500
ΦLuminaire -19074