Commercial Waste Pipe Network Design
Budget: $10 – $30 USD
I'm looking for an experienced civil engineer or architect to develop a design for an underground waste pipe network for a farm.
This project will handle waste from various toilets, portable showers and kitchens.
The ultimate goal is to minimize system clogs and maintain efficient waste transportation.
Please tell me why I should give you my project to work on.
I will pay $20 for this drawing.
I need dawings with calcullations.
These are my project details:
Waste Network Plan
Point A is the reference point.
Point A is at ground level 0.0 cm
Point B is at ground level -46 cm
The waste pipe Between Point A and Point B is to be buried at a depth of 110 cm
Distance between Point A and Point B is 35 meters
The waste pipe from Point A to Point B should have a drop level of 1.5 cm per meter
Point C is at ground level -110 cm
The waste pipe Between Point B and Point C is to be buried at a depth of 110 cm
Distance between Point B and Point C is 32 meters
Point A and Point B are in direct line with Point C
The waste pipe from Point B to Point C should have a drop level of 1.5 cm per meter
The septic tank would be positioned next to Point C.
Point D is coming from the opposite direction to Point C (Point A to D are in Straight Line)
Point D is at ground level -110 cm
Distance between Point D and Point C is 19 meters
The waste pipe from Point D to Point C should have a drop level of 1.5 cm per meter
The waste pipe Between Point D and Point C is to be buried at a depth of 110 cm
Point E is coming from the right to Point C at 90 degrees
Point E is at ground level -126 cm
Distance between Point E and Point C is 53 meters
The waste pipe from Point E to Point C should have a drop level of 1.5 cm per meter
The waste pipe Between Point E and Point C is to be buried at a depth of 110 cm
Point F is at ground level -20 cm
Point F is coming from the right to Point B at 90 degrees
Distance between Point F and Point B is 47 meters
The waste pipe from Point F to Point B should have a drop level of 1.5 cm per meter
The waste pipe Between Point F and Point B is to be buried at a depth of 110 cm
Point F will connect directly to point B
Point C is the point where the septic tank will be placed
Calculate the dept at of waste pipe as arriving at Point C
Calculate the dept of waste pipe as arriving from Point A to Point B taking into consideration the required 1.5 cm drop per metre.
Calculate the dept of waste pipe as arriving from Point B to Point C taking into consideration the required 1.5 cm drop per metre.
Calculate the dept of waste pipe as arriving from Point F to Point B taking into consideration the required 1.5 cm drop per metre.
Calculate the dept of waste pipe as arriving from Point E to Point C taking into consideration the required 1.5 cm drop per metre.
All pipes coming from Point B, Point E and Point D arriving at Point C must be on the same level.
This project will handle waste from various toilets, portable showers and kitchens.
The ultimate goal is to minimize system clogs and maintain efficient waste transportation.
Please tell me why I should give you my project to work on.
I will pay $20 for this drawing.
I need dawings with calcullations.
These are my project details:
Waste Network Plan
Point A is the reference point.
Point A is at ground level 0.0 cm
Point B is at ground level -46 cm
The waste pipe Between Point A and Point B is to be buried at a depth of 110 cm
Distance between Point A and Point B is 35 meters
The waste pipe from Point A to Point B should have a drop level of 1.5 cm per meter
Point C is at ground level -110 cm
The waste pipe Between Point B and Point C is to be buried at a depth of 110 cm
Distance between Point B and Point C is 32 meters
Point A and Point B are in direct line with Point C
The waste pipe from Point B to Point C should have a drop level of 1.5 cm per meter
The septic tank would be positioned next to Point C.
Point D is coming from the opposite direction to Point C (Point A to D are in Straight Line)
Point D is at ground level -110 cm
Distance between Point D and Point C is 19 meters
The waste pipe from Point D to Point C should have a drop level of 1.5 cm per meter
The waste pipe Between Point D and Point C is to be buried at a depth of 110 cm
Point E is coming from the right to Point C at 90 degrees
Point E is at ground level -126 cm
Distance between Point E and Point C is 53 meters
The waste pipe from Point E to Point C should have a drop level of 1.5 cm per meter
The waste pipe Between Point E and Point C is to be buried at a depth of 110 cm
Point F is at ground level -20 cm
Point F is coming from the right to Point B at 90 degrees
Distance between Point F and Point B is 47 meters
The waste pipe from Point F to Point B should have a drop level of 1.5 cm per meter
The waste pipe Between Point F and Point B is to be buried at a depth of 110 cm
Point F will connect directly to point B
Point C is the point where the septic tank will be placed
Calculate the dept at of waste pipe as arriving at Point C
Calculate the dept of waste pipe as arriving from Point A to Point B taking into consideration the required 1.5 cm drop per metre.
Calculate the dept of waste pipe as arriving from Point B to Point C taking into consideration the required 1.5 cm drop per metre.
Calculate the dept of waste pipe as arriving from Point F to Point B taking into consideration the required 1.5 cm drop per metre.
Calculate the dept of waste pipe as arriving from Point E to Point C taking into consideration the required 1.5 cm drop per metre.
All pipes coming from Point B, Point E and Point D arriving at Point C must be on the same level.