Restroom & kitchenette layout – detailed technical brief (EU standards)

Job ID: 40194452

Budget: €8 – €30 EUR

I am looking for an interior designer / space planner to prepare a precise and buildable 2D layout for a restroom block with kitchenette, designed strictly according to European (Czech / EU) building and hygiene standards.

This is a technical planning task, not a visual or conceptual design.

Please read carefully and follow the requirements below.

1. Project scope

One existing room only

No possibility to enlarge the space

Exact internal dimensions will be provided

Existing door openings should be preserved if reasonably possible
(they may be modified only if absolutely necessary)

2. Required sanitary program
Women’s restroom

2 WC cabins

wall-mounted WC bowls

each WC fixed to main structural wall only

no WC mounted on lightweight partitions

Minimum WC cabin dimensions:

width: 900 mm (minimum)

depth: 1,400 mm minimum
(1,500 mm preferred)

Doors:

clear width: 700–800 mm

opening outwards from the cabin (at least one WC must comply)

Men’s restroom

1 WC cabin

3 wall-mounted urinals

WC bowl and urinals fixed to main structural wall

WC cabin dimensions (same as women):

width: min. 900 mm

depth: min. 1,400–1,500 mm

Urinal spacing:

minimum width per urinal: 600 mm

recommended axis-to-axis spacing: 700–800 mm

minimum distance from urinal to sink: 400 mm preferred
(300 mm absolute minimum)

Privacy partitions between urinals are not mandatory, optional only.

Visibility rule (important)

WC bowls must NOT be directly visible
when opening the main entrance door to the WC area,
even if cabin doors are open.

The layout must avoid any direct visual axis to WC bowls.

3. Sinks (washbasins)

sinks must be provided in:

women’s area

men’s area

minimum:

1 sink per restroom

recommended:

women: 2 sinks

men: 1 sink

sinks must have hot and cold water

4. Kitchenette

located in the remaining part of the room

separate enclosed room

not pass-through to WC areas

separate entrance

minimum size: approx. 2.5 × 2.5 m

includes sink with hot and cold water

5. Ventilation (mandatory)

WC areas require mechanical exhaust ventilation

men’s WC and women’s WC must have separate exhaust branches

kitchenette must have its own, separate ventilation

WC ventilation and kitchenette ventilation must NOT be combined

Exhaust routing

the final exhaust point is already defined

its location is marked in blue on the provided plan

your layout must respect this exhaust location

ventilation ducts may pass through other rooms only as closed, sealed ducts

6. Domestic hot water boiler

include a realistic and accessible location for a domestic hot water boiler

boiler must:

be service-accessible

logically supply sinks and WCs

not obstruct circulation or door openings

placement must be technically realistic for Central European construction

7. Construction principles

all WC bowls and urinals must be:

wall-mounted

anchored to main structural walls only

minimize new partitions

avoid unnecessary complexity

the solution must be realistic, economical, and buildable

8. Deliverables

2D floor plan only

all key dimensions included

sanitary fixtures clearly labeled

ventilation routes indicated schematically

no 3D, no renderings, no decoration

If anything in this brief is unclear, please ask before starting the work.

Thank you.